PANTHER  

Definition

  • PANTHER uses Electron Capture Detection and Gas Chromatography (ECD-GC) and Mass Selective Detection and Gas Chromatography (MSD-GC) to measure numerous trace gases, including Methyl halides, HCFCs, PAN, N20, SF6, CFC-12, CFC-11, Halon-1211, methyl chloroform, carbon tetrachloride. 3 ECD (electron capture detectors), packed columns (OV-101, Porpak-Q, molecular sieve). 1 ECD with a TE (thermal electric) cooled RTX-200 capillary column. 2-channel MSD (mass selective detector). The MSD analyses two independent samples concentrated onto TE cooled Haysep traps, then passed through two temperature programmed RTX-624 capillary columns. With the exception of PAN, all channels of chromatography are normalized to a stable in-flight calibration gas references to NOAA scales. The PAN data is normalized to an in-flight PAN source of ≈ 100 ppt with ±5 % reproducibility. This source is generated by efficient photolytic conversion of NO in the presence of acetone. Detector non-linearity is taken out by lab calibrations for all molecules. (en)

Broader concept

Change note

  • 2022-04-18 13:07:47.0 [tstevens] Insert Concept add broader relation (PANTHER [2bb2fd20-fb6e-48d7-a22c-74fa4b6f205d,894379] - Chemical Meters/Analyzers [3d25724b-832f-4a61-b0b2-4f2ccecdba94,885712]);
  • 2022-04-18 13:09:01.0 [tstevens] insert AltLabel (id: null category: primary text: PAN and Trace Hydrohalocarbon ExpeRiment language code: en); insert Definition (id: null text: PANTHER uses Electron Capture Detection and Gas Chromatography (ECD-GC) and Mass Selective Detection and Gas Chromatography (MSD-GC) to measure numerous trace gases, including Methyl halides, HCFCs, PAN, N20, SF6, CFC-12, CFC-11, Halon-1211, methyl chloroform, carbon tetrachloride. 3 ECD (electron capture detectors), packed columns (OV-101, Porpak-Q, molecular sieve). 1 ECD with a TE (thermal electric) cooled RTX-200 capillary column. 2-channel MSD (mass selective detector). The MSD analyses two independent samples concentrated onto TE cooled Haysep traps, then passed through two temperature programmed RTX-624 capillary columns. With the exception of PAN, all channels of chromatography are normalized to a stable in-flight calibration gas references to NOAA scales. The PAN data is normalized to an in-flight PAN source of ≈ 100 ppt with ±5 % reproducibility. This source is generated by efficient photolytic conversion of NO in the presence of acetone. Detector non-linearity is taken out by lab calibrations for all molecules. language code: en);

URI

https://gcmd.earthdata.nasa.gov/kms/concept/2bb2fd20-fb6e-48d7-a22c-74fa4b6f205d

Download this concept:

RDF/XML TURTLE JSON-LD Last modified 12/6/20