Aerolaser AL5002  

Definition

  • The AL5002 from Aero-Laser is a fast carbon monoxide (CO) monitor with a unique sensitivity below 1ppb (parts per billion). The detection of CO is based on a VUV-fluorimetry, employing the excitation of CO at 150nm. This method combines high sensitivity with high selectivity and is linear from 1ppb to 100 ppm. The excitation light is generated by a CW-CO2 resonance lamp, which needs only low maintenance. A monochromator unit, using dielectric mirrors, filters out the VUV from the lamp’s spectrum. The fluorescence light in the wavelength range between 160 nm and 190 nm is detected by a VUV sensitive photomultiplier followed by a fast counter. The AL5002 calibrates within minutes, using only a small amount of calibration gas and an in-built zero gas source. The calibration procedure is fully automatic and can be scheduled in custom-set time intervals. The gas concentration is displayed in real-time and is logged via a standard RS-232 interface. Parameter/diagnostic information (e.g. of pressures, flows, temperatures) are logged simultaneously with the measurement data allowing fast troubleshooting of problems. (en)

Broader concept

Change note

  • 2021-05-10 13:44:28.0 [tstevens] Insert Concept add broader relation (Aerolaser AL5002 [e6e29103-5539-4638-a561-44cee176df9e,606913] - Chemical Meters/Analyzers [3d25724b-832f-4a61-b0b2-4f2ccecdba94,598603]);
  • 2021-05-10 13:47:02.0 [tstevens] insert AltLabel (id: null category: primary text: Aerolaser AL5002 CO Monitor language code: en); insert Definition (id: null text: The AL5002 from Aero-Laser is a fast carbon monoxide (CO) monitor with a unique sensitivity below 1ppb (parts per billion). The detection of CO is based on a VUV-fluorimetry, employing the excitation of CO at 150nm. This method combines high sensitivity with high selectivity and is linear from 1ppb to 100 ppm. The excitation light is generated by a CW-CO2 resonance lamp, which needs only low maintenance. A monochromator unit, using dielectric mirrors, filters out the VUV from the lamp’s spectrum. The fluorescence light in the wavelength range between 160 nm and 190 nm is detected by a VUV sensitive photomultiplier followed by a fast counter. The AL5002 calibrates within minutes, using only a small amount of calibration gas and an in-built zero gas source. The calibration procedure is fully automatic and can be scheduled in custom-set time intervals. The gas concentration is displayed in real-time and is logged via a standard RS-232 interface. Parameter/diagnostic information (e.g. of pressures, flows, temperatures) are logged simultaneously with the measurement data allowing fast troubleshooting of problems. language code: en);

URI

https://gcmd.earthdata.nasa.gov/kms/concept/e6e29103-5539-4638-a561-44cee176df9e

Download this concept:

RDF/XML TURTLE JSON-LD Last modified 12/6/20