@prefix skos: <http://www.w3.org/2004/02/skos/core#> .
@prefix ns0: <https://gcmd.earthdata.nasa.gov/kms#> .

<https://gcmd.earthdata.nasa.gov/kms/concept/3d25724b-832f-4a61-b0b2-4f2ccecdba94>
  skos:prefLabel "Chemical Meters/Analyzers"@en ;
  a skos:Concept ;
  skos:narrower <https://gcmd.earthdata.nasa.gov/kms/concept/46a21779-809f-43db-b196-f98af4f21e03> .

<https://gcmd.earthdata.nasa.gov/kms/concept/46a21779-809f-43db-b196-f98af4f21e03>
  ns0:reference [ ] ;
  ns0:altLabel [ ] ;
  skos:changeNote """2021-05-11 09:44:37.0 [tstevens]  
insert AltLabel (id: null
category: primary
text: Met one Instruments, Inc. BC 1050 Series Black Carbon Monitors
language code: en); 
insert Definition (id: null
text: The Met One Instruments, Inc. BC 1050 Series, Black Carbon Monitors, measures the absorption of particulate matter onto filter tape continuously. The BC 1050 monitor operates at 2-wavelengths and the BC 1054 operates at 10-wavelengths. The BC 1050 offers the user the ability to monitor absorption at near-IR (880 nm) and near-UV (375 nm) wavelengths simultaneously with a standard minimum time resolution of 1-minute. The BC 1054, multi-spectrum carbon monitor, measures the absorption at 375, 430, 470, 525, 565, 590, 660, 700, 880 and 950 nm with a standard time resolution of 1-minute. Optional 1-second time resolution is available for both the BC 1050 and the BC 1054.
language code: en); 
""", """2021-05-11 09:42:28.0 [tstevens] Insert Concept 
add broader relation (MetOne BC 1050 Black Carbon Monitors [46a21779-809f-43db-b196-f98af4f21e03,606927] - Chemical Meters/Analyzers [3d25724b-832f-4a61-b0b2-4f2ccecdba94,598603]); 
""" ;
  skos:broader <https://gcmd.earthdata.nasa.gov/kms/concept/3d25724b-832f-4a61-b0b2-4f2ccecdba94> ;
  skos:prefLabel "MetOne BC 1050 Black Carbon Monitors"@en ;
  skos:inScheme <https://gcmd.earthdata.nasa.gov/kms/concepts/concept_scheme/instruments> ;
  skos:definition "The Met One Instruments, Inc. BC 1050 Series, Black Carbon Monitors, measures the absorption of particulate matter onto filter tape continuously. The BC 1050 monitor operates at 2-wavelengths and the BC 1054 operates at 10-wavelengths. The BC 1050 offers the user the ability to monitor absorption at near-IR (880 nm) and near-UV (375 nm) wavelengths simultaneously with a standard minimum time resolution of 1-minute. The BC 1054, multi-spectrum carbon monitor, measures the absorption at 375, 430, 470, 525, 565, 590, 660, 700, 880 and 950 nm with a standard time resolution of 1-minute. Optional 1-second time resolution is available for both the BC 1050 and the BC 1054."@en ;
  a skos:Concept .